Innovative Brick Systems Total Tilt

UNIT MASONRY ASSEMBLIES 04810

Innovative Brick Systems, LLC

B. Product Data: Submit product data, including manufacturer’s SPEC-DATA® sheet, for specified products.

Specifier Note: Article below should include prerequisites, standards, limitations and criteria that establish an overall level of quality for products and workmanship for this section. Coordinate article below with Division 1 Quality Assurance Section.

C. Shop Drawings: Submit shop drawings showing details of form liner design and method of installation in formwork.

Specifier Note: The formwork section should call for a full-scale mock-up.

D. Samples: Submit a 1/4 scale concrete panel showing design and texture expected from the form liner.

1.04 QUALITY ASSURANCE

Specifier Note: Paragraph below should list obligations for compliance with specific code requirements particular to this section. General statements to comply with a particular code are typically addressed in Conditions of the Contract and Division 1 Regulatory Requirements Section. Repetitive statements should be avoided.

A. Regulatory Requirements and Approvals: [Specify applicable requirements of regulatory agencies.].

1. [Code agency name].

a. [Report or approval number].

Specifier Note: Article below should include special and unique requirements. Coordinate article below with Division 1 Product Requirements Section.

1.05 DELIVERY, STORAGE & HANDLING

A. General: Comply with Division 1 Product Requirements Section.

B. Delivery: Deliver materials in manufacturer's original, unopened, undamaged containers with identification labels intact.

C. Storage and Protection: Store materials protected from exposure to harmful environmental conditions and at temperature and humidity conditions recommended by the manufacturer. PART 2 PRODUCTS Specifier Note: Retain article below for proprietary method specification. Add product attributes, performance characteristics, material standards and descriptions as applicable. Use of such phrases as “or equal” or “or approved equal” or similar phrases may cause ambiguity in specifications. Such phrases require verification (procedural, legal and regulatory) and assignment of responsibility for determining “or equal” products.

2.01 FORM LINERS

Specifier Note: Paragraph below is an addition to CSI SectionFormat and a supplement to MANU-SPEC. Retain or delete paragraph below per project requirements and specifier's practice.

A. Manufacturer: Innovative Brick Systems, LLC.

1. Contact: 11625 Reed Ct., Broomfield, CO 80020; Telephone: (800) 413-4588, (720) 890-6032; Fax: (720) 890-6038; E-mail: info@mbrick.com; website: www.mbrick.com.

Specifier Note: Edit Paragraph below to suit project requirements. If substitutions are permitted, edit text below. Add text to refer to Division 1 Project Requirements (Product Substitutions Procedures) Section.

B. Substitutions: No substitutions permitted.

2.02 MANUFACTURED UNITS

A. VERSA LINER: Conform to brick bond and patterns indicated on the drawings.

1. Thickness: 20 mils (0.51 mm). 2. Weight: 0.142 psf (0.69 kg/m 2 ).

3. Tensile Strength (ASTM D638): 4080 psi (28,111 kPa) at yield.

4. Izod Impact (ASTM D256): 3.3 at 73 degrees F (23 degrees C).

SPEC-DATA ® and MANU-SPEC ® are registered trademarks of Reed Elsevier Inc. The three part MANU-SPEC format conforms to the editorial style of the Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2006 Reed Construction Data. All Rights Reserved.